IEC 61850 Ed.2 protocol concentrator integrating up to 64 substation IEDs via GOOSE and SV, converting to DNP3 Level 3, Modbus TCP/RTU, and ICCP TASE.2 for energy control SCADA, with IEC CIM configuration database, HSR/PRP substation network redundancy, IEEE 1588v2 PTP synchronization, and 1 ms SOE event recording.
Kalkitech
Kalkitech Mercury Gateway IEC 61850 Protocol Concentrator for Electrical Substations with DNP3 Modbus and ICCP Conversion
Technical specifications
Technical overview
The Kalkitech Mercury Gateway is the protocol concentrator designed for the Peruvian electricity distribution company that needs to integrate into its energy control SCADA the protection and control IEDs of a substation modernized with IEC 61850 Ed.2 — Siemens 7SD protection relays, ABB REF615 reclosers, Arteche electronic measuring transformers — with the existing SCADA server that only speaks DNP3 Level 3, because the cost of replacing the SCADA server and reprogramming all data points exceeds the cost of modernizing ten substations with IEC 61850 IEDs.
The automatic IEC CIM data mapping — Common Information Model from IEC 61970 standard — converts the semantic description of substation data in the IEC 61850 object model (LD, LN, DO, DA with quality and timestamp attributes) into the SCADA's DNP3 point representation, preserving data semantics — it is a circuit breaker state, not an anonymous binary value — in the destination DNP3 point through naming the point with the source attribute's IEC 61850 path, so the SCADA operator can see "IED_REL1/XCBR1.Pos.stVal" as the DNP3 point name instead of anonymous "AI_0042".
HSR network redundancy in the IEC 61850 substation process network guarantees GOOSE and Sampled Values message transfer with zero milliseconds fault recovery time, versus the 200-300 ms of standard RSTP protocol that is inadmissible for transformer differential protection trip GOOSE messages requiring maximum 4 ms latency per IEC 61850-5.
Applications
Related products
IEC 61850 / DNP3 / IEC 104 / Modbus substation gateway. Converts legacy IEDs to modern protocols without equipment replacement. Certified for transmission SCADA integration.
View details →KalkitechIEC 61968/61970 CIM integration gateway connecting heterogeneous SCADA, EMS, DMS, and GIS systems via an SOA service bus. Translates legacy data models (DNP3, IEC 60870, Modbus) to IEC CIM standard without modifying existing systems.
View details →KalkitechIEC 61850 conformance testing tool to validate standard implementation in IEDs, protection relays, and RTUs before commissioning. Generates conformance reports for KEMA/UL certification, simulates GOOSE and MMS failures, and validates manufacturer PIXIT/MICS model against the standard.
Technical guide for migrating legacy IEDs to IEC 61850 in SEIN substations. Digitalization protocol without equipment replacement, IEEE 1588 time synchronization, and COES-SINAC compliance.
Analysis of SEIN digitalization state and the 2030 roadmap: massive renewable integration, IEC 61850 Edition 2, IEC 62351 cybersecurity, distributed generation, and the role of communications infrastructure.
Local technical support
EMAR SYSTEMS provides integration, training, and after-sales support for all represented products. Contact the technical team for specifications, demos, and quotes.